SIGNALVAULT / CUSTOM RF SHIELDING

Custom RF Shielding: Planning & Procurement Resources

Practical project checklists and decision guides for finished rooms, vehicle covers and industrial equipment enclosures.

Make better procurement decisions

Project requirements checklist

RequirementRecord before review
ApplicationWhat needs shielding; intended activity; incoming signals, emissions or both
RF objectiveTarget frequencies and required attenuation, or the problem to investigate
DimensionsFinished internal space or full equipment envelope; tolerances and protrusions
AccessDoors, handles, opening frequency, maintenance and emergency access
ServicesPower, network, ventilation, cooling and every penetration
SiteCountry, delivery route, assembly clearance and local coordination
DeliveryManufacturing, freight, site work, installation, testing and handover owners
AcceptanceMethod, frequency points, locations, configuration, pass criteria and retest scope

Measure for the intended use

For rooms, distinguish finished internal dimensions, external enclosure footprint, installation clearance and the route for bringing components into the building. For equipment, include handles, connectors, projections and maintenance clearances. Record the configuration in which shielding will actually be used. Mark uncertain dimensions for survey rather than presenting them as production dimensions.

Frequency and attenuation targets

List the frequencies or systems that matter and the attenuation required at those frequencies. “All signals” is not a reproducible acceptance specification. Describe the environment and operating state. Where targets are unknown, start with the application and agree the necessary assessment. Material data and finished-system performance are different evidence.

Acceptance preparation checklist

  • Freeze the configuration to be tested, including closures and service entries.
  • Agree the measurement method, frequency points or ranges, positions and pass criteria.
  • Arrange site access, instrument setup and an appropriate test environment.
  • Record limitations and distinguish measured results from assumptions.
  • Include corrective work, retesting and final documentation in the scope.
  • Agree maintenance and retest triggers after later changes.

What establishes project capability?

A useful evidence pack connects the project brief to drawings, manufacturing records, installation checks and final results. Photographs should identify what is shown and its actual provenance. An application concept image cannot establish a delivered customer project or a measured shielding result.

EvidenceWhat it can supportWhat it does not establish alone
Company registrationLegal entity identity and registered addressFactory location, technical accreditation or project performance
Material documentationThe documented sample, construction and test conditionsThe performance of an assembled room or cover
Manufacturing and installation recordsWork performed and inspectable construction detailsCompliance with an unspecified acceptance requirement
Final test reportResults for its stated configuration, method and conditionsEvery frequency, operating state or future modification

Existing specification guides

Technical background

These independent manufacturer resources explain general engineering considerations. They are not certifications or endorsements of SignalVault.

Updated 13 November 2026. Planning information; project requirements and verification are agreed individually.